Enhanced particle detection unit goes down to 5um defects

10/07/2010

(October 7, 2010) -- Answering the growing demand for a high resolution, Dr. Schenk has developed an enhanced version of the Pollux Particle Detection System for Photomasks. Pollux-Enhanced automated particle detection system enables fabs to perform a complete inspection on each reticle prior to its use.

Pollux-E offers objective evaluation data for the pass/fail decision of lithographic photomasks. This approach provides a more cost-effective and more reliable solution than the method of visual inspection.

As the outside dimension of the new Pollux-E is the same as of Pollux, it can easily be integrated in the same reticle stockers or handling systems than the current Pollux. Pollux-E has been designed for integration into:

  • Reticle Stockers
  • Wafer Steppers
  • Cleaning Stations
  • Automatic Handling Systems

Pollux-E inspects the surface of the glass side and the pellicle surface of the chrome side for imperfections down to 5μm equivalent sphere diameter (ESD). Pollux-E detects particulate contamination and defects such as glass scratches and holes in the pellicle. Each fab can individually determine the threshold according to the minimum size of particles that are of interest.

Pollux-E offers highly reliable contamination control for the lithography process, independent of an operator performing a visual inspection, according to the company. Pollux-E automatically determines the frame height and the inspection area. No manual adjustment or parameter setting is needed to adapt the system for the reticle to be inspected. The average cycle time takes between 45 to 70 seconds.

Pollux-E uses a far dark-field laser inspection principle. Highly sensitive CCD line scan cameras collect the scattered light from any imperfetion. The size of detected particles is determined according to the number and intensity of bright pixels.

Pollux-E offers a user-friendly graphical user interface (GUI) according to SEMI standards. Pollux-E reports the number of detected particles on the surfaces of both sides of the reticle. Contamination data, such as the number of detected particles, ESD size and xy-coordinates, will be displayed in a defect map, defect table and defect size histogram, providing a quick overview.

Technical data:

  • Reticle Size: 6"
  • Detectability: >5μm (ESD)
  • Repeatablility: Particles 5-20μm (ESD) ≥90%
  • Particles >20μm (ESD) ≥98%
  • Threshold: Adjustable by customer according to the minimum size of particles of interest
  • Av. Cycle Time: ≈ 45-70sec.
  • Autofocus: for Frame Height Detection
  • User Interface: User-friendly GUI according to SEMI standards
  • Communication TCP/IP Ethernet-network with Interface: Windows DCOM or ActiveX Digital I/O
  • Cleanroom: Class 1 compatible
  • Laser Class: Class 1 Laser and LED product
  • Size (LxWxH): 713 x 341 x 400mm
  • System Weight: approx. 30 kg
  • Power Supply: 100-240 VAC, 50-60 Hz, 115 VA
  • Electro Static Discharge safe
  • CE Conformity
  • Plug and Play

Dr. Schenk GmbH information is available at www.drschenk.com

Subscribe to Solid State Technology/Advanced Packaging. Follow Solid State Technology on Twitter.com via editors Pete Singer, twitter.com/PetesTweetsPW and Debra Vogler, twitter.com/dvogler_PV_semi. Or join our Facebook group

Font Sizes:

POST A COMMENT

Easily post a comment below using your Linkedin, Twitter, Google or Facebook account. 


VIDEOS

Electroiq 2 EIQ2

TECHNOLOGY PAPERS

Automated Test Creation for Mixed Signal IP using IJTAG

The creation of test patterns for mixed signal IP has been, to a large extent, a manual effort. To improve the process used to test, access, and control embe...

Faster Time to Root Cause with Diagnosis-Driven Yield Analysis

This whitepaper describes the benefits of implementing a diagnosis-driven yield analysis flow using the Tessent® Diagnosis and Tessent YieldInsight® software...

WEBCASTS

Innovation in Semiconductor Manufacturing Instrumentation

As the industry is incorporating more MEMS devices with integrated magnetic sensors, they are encountering challenges that cannot be overcome with ...

3D and 2.5D Integration: A Status Report Live Event

This webcast will explore the present status of 2.5 and 3D integration, including TSV formation.

Questions and answers on FD-SOI

Fri Jan 04 14:56:00 CST 2013

Present your ideas at The ConFab in 2013

Mon Nov 26 09:04:00 CST 2012

The ConFab 2013 countdown begins

Thu Aug 09 16:18:00 CDT 2012

The ConFab: Big data is here

Sun Jun 03 19:19:00 CDT 2012

Oh, snap!: Pics from The ConFab

Sun Jun 03 19:09:00 CDT 2012

SUBSCRIBE

LATEST ISSUE

Volume 56, Issue 1

Article Archive for Solid State Technology.

© 2013. PennWell Corporation. All Rights Reserved. PRIVACY POLICY | TERMS AND CONDITIONS